| Profile 01 | Roadway and highway lighting poles | Hot-rolled carbon steel; commonly grades equivalent to S235, S275, or S355 under EN 10025 | EN 40; EN 1090 where structural fabrication is covered; IEC 60598-1 for compatible luminaires | Hot-dip galvanizing to ISO 1461 or ASTM A123; optional polyester powder coating | Single or double outreach arms, flange or embedded bases, access doors, cable holes, and tenon dimensions | Tube forming, longitudinal welding, CNC plate cutting, robotic or manual welding, drilling, and galvanizing | Dimensional inspection, weld inspection, coating thickness measurement, and structural design verification | Municipal roads, highways, interchanges, and large outdoor infrastructure projects |
| Profile 02 | Urban street and pedestrian-area poles | Galvanized steel, aluminum alloys, or weather-resistant steel depending on design requirements | EN 40, IEC 60598-1, IEC 60598-2-3, and local electrical installation requirements | Zinc coating, powder coating, anodizing for aluminum, or multi-layer decorative systems | Decorative profiles, curved arms, heritage-style details, custom colors, banners, and maintenance doors | Extrusion or roll forming, CNC bending, welding, polishing, coating, and assembly | Appearance inspection, dimensional checks, coating adhesion testing, and corrosion-resistance evaluation | City centers, parks, promenades, campuses, residential streets, and public plazas |
| Profile 03 | High-mast lighting towers | High-strength structural steel with engineered base plates and segmented shafts | EN 40, EN 1993 structural calculations, IEC 60598 requirements for lighting equipment, and local wind codes | Hot-dip galvanizing to ISO 1461 or ASTM A123; duplex coating for severe environments | Multi-level platforms, raising-and-lowering systems, maintenance winches, aviation markers, and custom headframes | Heavy plate rolling, tapered-section welding, precision flange fabrication, lifting-system assembly, and site engineering | Wind-load calculations, weld testing, bolt verification, dimensional control, and raising-system functional testing | Ports, airports, logistics yards, sports facilities, industrial sites, and large parking areas |
| Profile 04 | Solar street-light poles and integrated solar systems | Galvanized steel or aluminum pole shafts with steel or aluminum solar-panel brackets | EN 40, IEC 60598-1, IEC 60598-2-3, IEC 62133 for applicable batteries, and IEC 61215 for photovoltaic modules | Hot-dip galvanizing, powder coating, and sealed electrical enclosures rated according to installation conditions | Panel tilt and azimuth, battery-box placement, controller compartments, foundation design, and smart-lighting interfaces | Pole forming, bracket welding, enclosure fabrication, photovoltaic mounting, wiring, and system commissioning | Battery protection checks, photovoltaic electrical testing, ingress protection review, wind-load calculation, and lighting autonomy testing | Off-grid roads, rural access routes, developing infrastructure, parks, and sites with limited grid availability |
| Profile 05 | Decorative and architectural lighting columns | Steel, cast aluminum, extruded aluminum, stainless steel, or engineered composite components | EN 40, IEC 60598-1, IEC 60598-2-3, and project-specific architectural specifications | Powder coating, liquid coating, anodizing, brushed stainless finish, or duplex corrosion protection | Ornamental bases, fluting, finials, custom silhouettes, integrated planters, banners, and concealed wiring | CNC machining, casting, spinning, metal forming, precision welding, polishing, and decorative finishing | Color consistency, surface-finish inspection, dimensional verification, corrosion testing, and sample approval | Hotels, resorts, commercial districts, waterfront developments, historic areas, and premium landscaping projects |
| Profile 06 | Industrial, warehouse, and logistics-area poles | Structural carbon steel with reinforced base plates and heavy-duty access components | EN 40, EN 1090 where applicable, ISO 1461, and local industrial electrical codes | Heavy hot-dip galvanizing; optional epoxy primer and polyurethane or powder topcoat | Higher luminaire loads, multiple outreach arms, camera brackets, cable trays, and reinforced inspection doors | Heavy-gauge plate processing, press braking, automated welding, machining, galvanizing, and load-rated assembly | Load calculations, weld visual inspection, coating thickness measurement, base-plate checks, and bolt-torque verification | Factories, distribution centers, container yards, mining sites, and industrial compounds |
| Profile 07 | Aluminum light poles for coastal and corrosion-sensitive locations | Structural aluminum alloys such as 6061 or 6063, selected according to design and extrusion requirements | EN 40, relevant aluminum structural design requirements, IEC 60598-1, and project wind standards | Anodizing, marine-grade powder coating, or compatible conversion and sealing treatments | Tapered extrusions, custom cross-sections, lightweight outreach arms, concealed cable routing, and special finishes | Extrusion, CNC cutting, bending, TIG or MIG welding, machining, anodizing, and powder coating | Alloy verification, dimensional inspection, weld examination, coating thickness checks, and salt-spray evaluation where specified | Coastal roads, marinas, resorts, pedestrian zones, and projects prioritizing low weight and corrosion resistance |
| Profile 08 | Smart-city and connected lighting poles | Galvanized steel or aluminum with modular equipment mounting zones | EN 40, IEC 60598-1, IEC 60598-2-3, IEC 62386 for DALI-based control systems where specified, and local ICT requirements | Hot-dip galvanizing, powder coating, or anodizing with sealed compartments and weather-resistant glands | Sensor ports, communication cabinets, CCTV brackets, public-address equipment, EV-related accessories, and modular nodes | Pole fabrication, modular bracket production, enclosure assembly, cable management, and electrical integration | Ingress protection review, electrical continuity, grounding, load calculations, interface checks, and network-device fit testing | Connected streets, traffic corridors, public Wi-Fi zones, surveillance networks, and urban technology projects |
| Profile 09 | Sports-field and area-lighting masts | High-strength steel shafts, service platforms, and engineered luminaire brackets | EN 40, applicable structural Eurocodes or local wind codes, IEC 60598-1, and sports-lighting project specifications | Hot-dip galvanizing, duplex coating systems, or high-durability paint systems for aggressive environments | Multiple floodlight arrays, aiming platforms, maintenance ladders, cable trays, anti-climb features, and access systems | Tapered shaft fabrication, heavy welding, platform assembly, ladder installation, galvanizing, and site erection support | Wind and vibration assessment, structural calculations, weld inspection, access-system testing, and aiming-platform verification | Stadiums, training grounds, tennis facilities, sports complexes, and large recreational areas |
| Profile 10 | Export-oriented project and private-label pole production | Carbon steel, aluminum, stainless steel, and mixed-material assemblies selected from approved project specifications | EN 40, ASTM A123 or ISO 1461 for galvanizing, ISO 9001 quality systems, and destination-market requirements | Hot-dip galvanizing, powder coating, liquid paint, anodizing, or duplex systems with documented inspection records | Buyer drawings, packaging marks, multilingual manuals, private-label documentation, special cartons, and container-loading plans | Flexible fabrication using CNC cutting, bending, welding, machining, coating, assembly, and export packing lines | Pre-production samples, first-article inspection, material certificates, coating reports, dimensional reports, and third-party inspection coordination | Distributors, engineering contractors, public tenders, OEM programs, and multi-country procurement projects |